Fiber Optic probe system:Inno Opt-Rum

The uniquely designed J-shaped probe significantly reduces interference from undissolved particles, ensuring reliable measurements even during dissolution testing.

With XSOF’s J-shaped probe. Configured by Spectra-coop. Built for pharmaceutical performance.

CONTACT
YouTube Video
× Close
Problems

Less Setup. Real-Time Insight.

Compared to HPLC, fiber optic probes offer several advantages such as real-time data acquisition, reduced preparation requirements, and elimination of filtration costs. However, in dissolution testing, undissolved particles can reduce measurement accuracy or make measurement impossible. The J-shaped probe is designed to solve this issue.

Real-time data acquisition

With HPLC, results are sometimes not available until the following day or later.

Preparation workload

Preparation can take several hours.

Running cost

The cost of filters and columns can add up significantly.

Our Solution

What Makes This Fiber Optic Probe System Unique

Enables easy testing with accurate, real-time results.

Real-time results, hassle-free setup, and virtually no running costs.

The fiber optic probe system delivers real-time data (less than 1-second intervals), allowing immediate results and quick transitions to the next reserch. Easy calibration and minimal setup reduce workload, and the long probe life means virtually no daily testing costs.

Strong points of J-shaped probe

The fiber optic probe system has traditionally been used for API concentration measurement. With the J-shaped probe minimizing particle interference, it is now also suitable for dissolution testing. Straight probes are, of course, also supported.

Software

The software is optimized with measurement methods such as second-derivative analysis, allowing accurate detection even in cases of overlapping peaks.

J shaped probe 30°and 90°
Probe Tips
Product Details

Can be installed on your current dissolution tester.

J-shaped vs straight

Innovative J-shaped Probe

「Developed by XSOF, the innovative J-shaped probe solves the persistent issue of measurement failure due to particle interference. It outperforms conventional straight probes, providing superior stability and confidence not found in other systems.

Dissolution testing conducted with OTC ibuprofen tablets
It has been confirmed that the J-shaped probe can perform measurements reliably even in conditions where straight probes fail.
Graph1
J shaped probe: A significant reduction in particle interference was observed.
Graph2
Straight probe :Unable to obtain accurate measurements because of powder-related interference.

Flexible system configuration

Dedicated Software: Process Viewer
  • Multilingual software for dissolution testing
  • Supports CSV export and Part 11 compliance
  • Concentration control functionality
  • Batch calibration for multiple probes
  • Real-time measurement at all points
  • Recalculation and derivative analysis supported
XSOF社製プローブ
Also for API mesurement
#
Also configurable for low-volume concentration measurement.
多様なプローブオプション

Various probe options

In addition to the J-shaped probe, a variety of straight probes are available, including options resistant to chemicals and high temperatures. Thin probes with a 1.6 mm diameter and path lengths of 1, 2, 5, 10, and 20 mm are also selectable.

Highly expandable system architecture

Compatible with existing dissolution testers, expandable up to 8 units, and adaptable for other applications.

Options and Related Products

GIS-α: Dissolution Tester for in vivo Prediction
胃消化シミュレーター:GDS Physiological-mimicking dissolution tester for transfer model prediction.

>>Details

Gastric digestion simulator:GDS
胃消化シミュレーター:GDS A simulator capable of reproducing gastric motility and physiological conditions

>>Details

FAQ

よくあるご質問

Yes. Needs to be checked in advance.

>>Contact

J-shaped probe can redue in particle interference

All probes can be calibrated simultaneously in a single step.

Yes.

We are open to customization requests. Please consult us for any specific requirements.

>>Contact

Yes.Can be used for dissolution testing, API concentration analysis, and related applications.

>>Contact